AS 4046.5-2002 amd1-2006 PDF
Name in English:
St AS 4046.5-2002 amd1-2006
Name in Russian:
Ст AS 4046.5-2002 amd1-2006
Original standard AS 4046.5-2002 amd1-2006 in PDF full version. Additional info + preview on request
Full title and description
AS 4046.5-2002 (Amdt 1-2006) — Methods of testing roof tiles — Determination of permeability. Specifies a standardized laboratory procedure for measuring the permeability (water penetration) of roof tiles under defined test conditions; includes the 2006 amendment incorporated into the 2002 edition.
Abstract
This standard defines the test method used to determine the permeability of roof tiles. It describes required apparatus, specimen preparation and conditioning, the test procedure for applying water under specified conditions, measurement and calculation of water penetration, and reporting requirements. The document was issued as the second edition in 2002 and reissued to incorporate Amendment 1 in 2006 (reconfirmation recorded in 2015).
General information
- Status: Current (reissued incorporating Amendment 1-2006; reconfirmed 2015).
- Publication date: 30 October 2002 (Amendment 1 issued January 2006).
- Publisher: Standards Australia.
- ICS / categories: 91.100.25 — Terracotta building products / Roofing materials and components.
- Edition / version: 2nd edition 2002, incorporating Amendment No.1 (2006).
- Number of pages: 3 (official Standards Australia product listing).
Scope
Sets out a laboratory method for determining the permeability of roof tiles — that is, the tendency for water to pass through or around a tile under specified testing conditions. The procedure is intended for use with roof tiles in both quality control and type-testing contexts and complements other tests in the AS 4046 series dealing with tile distortion, freeze–thaw resistance and other performance characteristics.
Key topics and requirements
- Definitions and terminology relevant to permeability testing of roof tiles.
- Required test apparatus and fixtures (water supply, heads, mounting rigs and detectors for penetration).
- Specimen selection, conditioning and mounting procedures to ensure repeatability.
- Step-by-step test procedure: application of water, exposure times, and measurement of penetration.
- Calculation and expression of test results (reporting of numeric permeability/penetration outcome and any observation of leakage paths).
- Reporting format and information to be recorded (test conditions, specimen identification, results, deviations).
- Notes on interpretation and relationship to other AS 4046 series tests.
Typical use and users
Used by tile manufacturers for quality control and product development, independent test laboratories conducting type and compliance testing, building product certifiers, architects and specifiers assessing product suitability for applications, and regulators or consultants evaluating roof covering performance under water exposure conditions.
Related standards
Part of the AS 4046 series of roof-tile test methods (for example AS 4046.1, AS 4046.6 etc.). It is commonly used alongside AS 2049 (Roof tiles) and other product- and performance-related Australian Standards that address tile dimensions, distortion, freeze/thaw resistance and installation practice.
Keywords
roof tiles; permeability; water penetration; test method; Standards Australia; AS 4046; amendment 2006; tile testing; quality control.
FAQ
Q: What is this standard?
A: AS 4046.5-2002 (Amdt 1-2006) is an Australian Standard that specifies a laboratory method for determining the permeability (water penetration) of roof tiles. It is the 2002 second edition with Amendment 1 issued in 2006.
Q: What does it cover?
A: It covers apparatus, specimen preparation and mounting, the stepwise test procedure for applying water, measurement and calculation of penetration, and reporting requirements for permeability testing of roof tiles.
Q: Who typically uses it?
A: Tile manufacturers, independent testing laboratories, product certifiers, architects, specifiers and building consultants use this standard for type testing, quality control and product assessment.
Q: Is it current or superseded?
A: The 2002 edition was reissued incorporating Amendment 1 (2006) and has been reconfirmed (2015). Users should check Standards Australia or authorized distributors for the very latest status or any subsequent revisions.
Q: Is it part of a series?
A: Yes — it is one part of the AS 4046 series of methods of testing roof tiles, which includes other parts addressing distortion, freeze/thaw resistance and related performance tests.
Q: What are the key keywords?
A: Permeability, water penetration, roof tiles, test method, AS 4046, Standards Australia, amendment 2006.